THE PROFESSIONAL
ELECTRICAL REPORT –
BASED ON YOUR PHOTOS

Upload property photographs and receive a professional electrical report prepared by a qualified electrician.

Prepared by qualified electriciansProfessional review and assessment by UK qualified electricians
No home visits or appointments100% remote visual assessment completed in your own time
Fast digital deliveryClear, downloadable & print-ready report sent straight to your email
No technical knowledge requiredSimple, step-by-step guided photo submission
Complete at your own paceSave and resume your walkthrough anytime on any device
Check My Electrics Report Preview

Snap. Send. Receive.

Our guided mobile-first process makes obtaining a professional visual electrical report quick, simple and straightforward.

1SNAP

No technical knowledge needed – we’ll guide you step-by-step through taking the photographs required for your report.

2SEND

Upload your photos securely through the Check My Electrics portal.

3RECEIVE

Receive a professional visual electrical report within 72 hours.

Check My ElectricsCheck My Electrics

VISUAL ELECTRICAL INSIGHT REPORT

Visual safety audit based on digital photographs supplied of the property.

CLIENT DETAILS

Client: [REDACTED]

Representative: [REDACTED] (Estate Agent: 0191 [REDACTED])

PROPERTY DETAILS

Address: [REDACTED], Gateshead, NE9 6RX

Property Type: 3-BEDROOM SEMI-DETACHED (RESIDENTIAL)

Approximate Age: 1970s

REPORT DETAILS

Reference: CME-20260608-SF45

Audit Date: 08 June 2026

Assessor: CME Safety Assessor #[REDACTED]

82%Health Index
OVERALL ASSESSMENT
RED FLAG RISK
Immediate Attention Required
1RED OBSERVATION (Safety Hazard)
3AMBER OBSERVATIONS (Recommendations)
12GREEN OBSERVATIONS (Satisfactory)
⚠️ PRIORITY WARNING: Red observations indicate potential safety hazards or non-compliance issues that pose an immediate risk. It is strongly recommended that these are investigated and rectified by a registered electrical contractor as a priority.
ℹ️ IMPORTANT NOTE: This report is based solely on photographs supplied and does not include any physical inspection, testing or certification.

đź“‹ OVERALL ASSESSMENT SUMMARY

"Following a remote visual inspection of the photographs supplied, the installation has been assessed. A red flag was identified on the kitchen ceiling heat detector, which is expired and requires immediate replacement. Amber recommendations are noted for main bonding clamps, extractor fan isolation, and surge protection. The remaining installations are generally satisfactory."

15-POINT VISUAL SAFETY CHECKLIST

Summary of visual inspections performed on the submitted photographs of domestic electrical infrastructure.

Consumer Unit Enclosure

Metal-clad BS EN 61439-3 compliant

PASS

Main Switch Isolation

Emergency isolator access & visibility

PASS

RCD Protection (30mA)

Direct contact hazard protection check

PASS

Surge Protection (SPD)

BS 7671:2018 transient overvoltage safety

WARNING

Main Service Cut-out

Visual fuse seal & service head condition

PASS

Electricity Meter

Visual condition & terminal cover integrity

PASS

Incoming Supply Tails

25mm double-insulated conductor sizing

PASS

Main Earthing Conductor

System earthing connection secure

PASS

Water Main Bonding

Equipotential protection conductor clamp

PASS

Gas Main Bonding

Equipotential connection & safety tag

WARNING

Kitchen Heat Detector

BS 5839-6 operational lifespan limit

HAZARD

Hallway Smoke Alarm

Fire detection alarm level check

PASS

Bathroom Fan Isolation

Local 3-pole maintenance isolator switch

WARNING

Socket Outlet Faces

Visual cracks, heat damage & wear check

PASS

Lighting Accessories

Pendant flexes, rose fittings & switches

PASS

PHOTOGRAPHIC EVIDENCE & ANALYSIS

🚨

IMMEDIATE HAZARDS - ACTION REQUIRED

Expired heat detector
EXPIRED
HAZARD

Kitchen - Heat Alarm Expiry (Fire Safety Warning)

Location: Kitchen CeilingBS 7671 Regulation: Part C1 equivalent (5839-6 operational life limit)

The kitchen heat detector has a manufacturer date stamp of May 2014. Operational lifespan is restricted to 10 years by the manufacturer. Expired sensors cannot be guaranteed to operate correctly in emergency situations, creating a critical safety hazard.

Required Action: Replace the heat alarm unit immediately with an interlinked BS EN 14604 compliant mains-powered detector.
⚠️

WARNINGS & RECOMMENDED UPGRADES

Consumer unit Breakers
NO SPD
RECOMMENDATION

Consumer Unit - Surge Protection Device (SPD) Missing

Location: Main Hallway CupboardBS 7671 Regulation: Chapter C3 equivalent (Section 443 transient overvoltage protection)

The consumer unit is a modern metal-clad dual RCD board, but does not feature an integral Surge Protection Device (SPD). Current UK BS 7671 wiring standards require SPDs to defend electronic equipment from overvoltage spikes caused by supply faults or lightning transients.

Recommended Upgrade: Have a registered electrician retro-fit an SPD module to protect home electronics.
Gas main bonding clamp
RECOMMENDATION

Earthing & Utilities - Gas Main Bonding Label Missing

Location: External Gas Meter BoxBS 7671 Regulation: Regulation C3 equivalent (Section 514 safety labeling requirements)

The protective equipotential bonding conductor is clamped to the gas pipe correctly, but the mandatory safety notification label ("SAFETY ELECTRICAL CONNECTION - DO NOT REMOVE") is missing.

Recommended Upgrade: Apply a compliant safety label clamp to prevent accidental disconnection.
Bathroom fan isolator
RECOMMENDATION

Bathroom - Extractor Fan Local Isolation Switch Missing

Location: Bathroom Ceiling/Enclosure OuterBS 7671 Regulation: Regulation C3 equivalent (Section 537 local isolation devices)

The bathroom extractor fan is wired directly into the lighting loop without a local 3-pole fan isolator switch, preventing isolation for maintenance without turning off the entire lighting circuit.

Recommended Upgrade: Install a 3-pole fan isolator switch outside the bathroom entrance.
âś…

COMPLIANT INSTALLATIONS - SATISFACTORY

Electricity meter
SATISFACTORY

Incoming Supplies - Service Cut-out & Meter Seals

Location: Main Service Entry PointBS 7671 Regulation: Chapter 13 satisfactory

The main cut-out service fuse (100A) and electrical service head are clean and dry. Meter tails are 25mm double-insulated, and physical supplier security seals are intact on both the meter and the cutout enclosure.

Ceiling light fittings
SATISFACTORY

Lighting Accessories & Bedroom Pendants

Location: Master & Secondary BedroomsBS 7671 Regulation: Section 559 satisfactory

Bedroom light fittings, pendant drops, and ceiling roses are in good visual condition. No evidence of cracks, overheating, or exposed conductors. Accessories are secure and fully enclosed.

LIMITATION OF LIABILITY & LEGAL DISCLAIMER: This visual safety report provides an early-stage assessment based solely on client-supplied digital photographs. No physical dismantling, tools, or calibrated electrical instruments were used. This report identifies obvious visual defects only and is not a statutory Electrical Installation Condition Report (EICR) as required by current Landlord Legislation. Hidden, internal, or buried wiring faults cannot be detected. Check My Electrics™ accepts no liability for incidents arising from hidden defects. A physical EICR inspection remains the standard recommendation for property transactions.

REPORT SIGNED OFF BY:

Auditor #[REDACTED]

CME Visual Safety Inspector, Check My Electrics Safety Team

CME Verification Assessor ID: CME-UK-[REDACTED]

* CHECK MY ELECTRICS * SAFETY VERIFIED *CME UK
Report Prepared by: CME Safety Team [REDACTED]System Web Portal: check-my-electrics.co.ukSupport: enquiries@check-my-electrics.uk | [REDACTED]
OUR SERVICE STANDARDS
Non-InvasiveNo wall cutting or physical disruption
Photo-BasedSimple photo upload process
No Testing UndertakenPurely visual assessment scope
Electrician InsightExpert guidance without the booking
Mobile FriendlyWorks on iPhone, iPad & Android
TAILORED FOR EVERY PROPERTY CLIENT
HomeownersVisual checks prior to renovations
HomebuyersPre-purchase electrical clarity
LandlordsTenancy visual health audits
Estate AgentsSpeed up property transactions
SurveyorsSupplement building surveys
Facilities MgtMulti-unit portfolio reviews
Property InvestorsFast due diligence assessment
HomeownersVisual checks prior to renovations
HomebuyersPre-purchase electrical clarity
LandlordsTenancy visual health audits
Estate AgentsSpeed up property transactions
SurveyorsSupplement building surveys
Facilities MgtMulti-unit portfolio reviews
Property InvestorsFast due diligence assessment

Built For Modern Property Care

We combine the speed of remote photo submission with the safety assurance of professional registered UK electricians.

Taking photos of domestic consumer unit on smartphone1. Fast Mobile Capture

10-Minute Guided Photo Upload

Our mobile checklist guides you step-by-step through photographing your fuseboard, meters, and accessories. No tools, testing, or home visits required.

UK Qualified Electrician reviewing electrical report2. UK Qualified Electricians

Expert Human Review & Insights

Every assessment is evaluated by registered UK electricians. You receive clear Red, Amber, and Green findings with actionable next steps within 72 hours.

NO APPOINTMENT REQUIRED

Complete the entire process from your phone in as little as 10 minutes, without arranging a site visit or waiting for an electrician.

GUIDED PHOTO SUBMISSION

Our simple step-by-step process shows you exactly which photographs to take. No testing, tools or technical knowledge required.

PREPARED BY QUALIFIED ELECTRICIANS

Every report is prepared and reviewed by qualified electricians, providing expert insight into the visible condition of your electrical installation.

PROPERTY-SPECIFIC REPORT

Every report is individually prepared using the photographs from your property. No templates, automated checklists or generic assessments.

CLEAR NEXT STEPS

Receive straightforward Red, Amber and Green findings, together with practical recommendations to help you make informed decisions with confidence.

READY TO DOWNLOAD & SHARE

Your professionally presented visual electrical report is delivered to your inbox within 72 hours as a PDF, ready to save, print or share whenever you need it.

What We Analyse

Using our guided photo submission process, qualified electricians assess visible areas of the electrical installation for indicators relating to installation age, safety protection, historic alterations, deterioration and other commonly identified electrical concerns.

Consumer Units, Protection & Installation Age

Visible indicators relating to consumer unit age, safety protection, historic alterations and overall installation condition.

Incoming Supply, Earthing & Electrical Integrity

Assessment of visible incoming supply arrangements, earthing, bonding and other indicators relating to the integrity and safety structure of the electrical installation.

Wiring Systems, Accessories & General Condition

Visible signs of deterioration, ageing wiring systems, damaged accessories and other commonly identified electrical concerns.

Historic Alterations & Installation Standards

Visible indicators of historic modifications, DIY alterations, workmanship standards and potentially non-compliant installation practices.

Safety Features & Property Protection Measures

Assessment of visible electrical safety features including protective devices, alarm systems and other commonly identified safety-related installations.

Overall Electrical Installation Insight

Qualified electricians assess visible indicators relating to installation age, maintenance standards, safety considerations and the overall condition of the property’s electrical installation.

Why Choose Check My Electrics

Professional visual electrical reports designed to help you make informed property decisions, quickly and confidently.

Qualified UK Electricians

All photo audits are carried out by fully qualified, registered UK electricians conforming to safety standards, ensuring you receive professional-grade observations.

Speed Up Property Deals

Ideal for home buyers, sellers, estate agents, and landlords looking to flag apparent electrical concerns instantly before arranging physical invasive EICRs.

Professional PDF Outputs

Receive a clear, concise visual electrical overview report utilising a simple traffic-light RAG system, easily print-ready and white-labeled under our safety team.

SaaS Credit Management

High-volume surveyors can buy credit packs in bulk and run assessments seamlessly under an organisation dashboard with zero checkout friction.

Simple, Transparent Pricing

Whether you are an individual homeowner or a busy property surveyor, choose the package that fits your visual audit volume.

Individual Plan

Homeowner Report

Perfect for single property visual safety checks

ÂŁ46/ single report
  • 12-Step Guided Photo Capture Wizard
  • Reviewed by qualified UK registered electricians
  • Comprehensive PDF Visual Electrical Report
  • No contracts, no subscriptions, no ongoing commitment
  • Emailed directly to your inbox within 72 hours
Get Your Report Now
Surveyor Packs

Business Credit Packs

Pre-paid credits for surveyors, estate agents, and landlords

10 Reports
ÂŁ420
Save ÂŁ40
20 Reports
ÂŁ800
Save ÂŁ120
30 Reports
ÂŁ1,140
Save ÂŁ240
30+ Reports
Enterprise
Custom Discounts
  • All report credits valid for 12 months
  • Dedicated B2B balance portal and credits ledger
  • 1-click email deduction at checkout (zero Stripe forms)
  • White-labeled report output for professional client folders
Access B2B Credit Portal

Frequently Asked Questions

Got questions? Here are quick answers to the most common queries about our remote visual electrical assessments.

Simply upload property photographs of your consumer unit, sockets, meter and key installations via our guided intake wizard. Our UK-qualified registered electricians perform a remote visual assessment and deliver your report straight to your inbox within 72 hours.

No. Check My Electrics™ provides a visual-only electrical safety insight based on photos. It does not replace a statutory Electrical Installation Condition Report (EICR) and does not involve physical electrical testing or dismantling of accessories.

Our visual report is ideal for homebuyers, sellers, landlords, estate agents and surveyors who require a fast, non-invasive overview of visible electrical components to identify obvious safety hazards or outdated fittings before proceeding with transactions or renovations.

Once your photos are uploaded and details confirmed, our team will review the media and email your report in PDF format within 72 hours.

If our report flags potential safety hazards (Red observations), it is strongly recommended that you contact a local registered electrician to inspect the installation physically and rectify the highlighted issues.

Get In Touch

Have questions about our reports or need custom support? Reach out to our support.

Customer support specialist answering phone enquiries

Contact Details

Send Us a Message

EICR LIMITATION POLICY

Does This Replace An EICR?

No. Importantly, Check My Electrics™ does not replace nor supersede an Electrical Installation Condition Report (EICR).

A full EICR remains the recommended route where a complete electrical inspection, testing and certification process is required.

Check My Electrics™ provides a fast, affordable, non-invasive visual electrical overview based on client-supplied photographs. The service is designed for homeowners, buyers, sellers, landlords and property professionals who want a clearer understanding of the visible condition of an electrical installation before committing to further inspections, purchases or remedial works.

The report helps identify visible electrical concerns, potential safety issues and areas that may require further investigation by a qualified electrician, providing an early-stage insight into the overall visible condition of the installation.